- Company
- Occupational safety
- Compliance
- Regulations and certificates
- Vacansies
- Management System
- Technical documentation
- Certificates
Series 12M55NG

|
Gas piston engine model |
Nominal rotation speed, min-1 |
Engine power |
Generator power |
Boost type |
Control type |
||||
|
Prime Power (PRP), kW |
Continuous Power (COP), kW |
Prime Power (PRP) |
Continuous Power (COP) |
||||||
|
kW |
kVA |
kW |
kVA |
||||||
|
12M55G6N0/5 |
1500 |
- |
1588 |
- |
- |
1500 |
1875 |
T/Vod-V |
ECU |
Designation: T/Vod-V = Turbocharger / CVB type "Water-Air".
Standard equipment
|
Cylinder block and piston group |
Air supply and exhaust systems |
|
Cast iron cylinder block. Inspection hatches for servicing each cylinder. Power structure of the crankcase/oil pan. Flywheel housing with additional space for installing a barring device. Individual cylinder heads. 4 valves per 1 cylinder. Forged crankshaft made of hardened steel with induction hardened main journals, connecting rod journals and fillets. Lightweight pistons with cooling and high-quality piston rings. |
Overhead turbochargers optimized for the generator set. Air filters with clogging indicators. Thermal insulation of turbochargers, exhaust manifolds and pipes. Fuel system The engine runs on a lean fuel mixture. External mixture formation in the mixer. Electronic control system. Natural gas is used as fuel. Gas line included (without certificates). Electrical system Electric starter 24V. Charging generator 55A. Set of basic sensors. Flywheel housing and flywheel SAE 00 flywheel housing and 21” flywheel. |
|
Cooling system |
|
|
Cooling system with gear-driven coolant pumps. Engines are supplied without a cooling unit. |
|
|
Lubrication system |
|
|
Full-flow fine oil filters with bypass valve. Water-oil heat exchangers. Centrifugal oil filters. |
|
Diesel engine model |
Nominal speed Min-1 |
«L» Length*, mm |
«W» Width*, mm |
"N" Height*, mm |
"Dry" Weight, kg |
||||
|
12M55G6N0/5 |
1500 |
3060 |
1990 |
2420 |
9600 |
||||
|
|
|||||||||
|
Continuous Operation Power (COP) |
Primary Operation Power (PRP) |
||||||||
|
Continuous power is the maximum power of the generating set when operating on a constant load without limitation of the operating time per year with breaks for maintenance in accordance with the manufacturer's instructions. |
Prime power is the maximum power of the generating set when operating on a variable load without limitation of the operating time per year with breaks for maintenance. For continuous operation over 24 h, the average permissible power shall not exceed 70% of the prime power (PRP). When determining the average actual power variable power values that make up less than 30% of the prime power are taken as 30%, and downtime is not taken into account.
|
||||||||
|
Maintenance Scheduled maintenance every 750 engine hours. Extended service interval based on oil analysis. Operating time before major repairs is at least 60,000 engine hours. Engine life, taking into account three major repairs, is at least 240,000 engine hours.
|
|||||||||
|
Standard fuel gas parameters |
|
|
|
|
|||||
|
Net heating value |
> |
36 |
MJ/m³ |
|
|||||
|
Methane content |
> |
80 |
% |
|
|||||
|
Rate of pressure change |
≤ |
1 |
kPa/min |
|
|||||
|
Hydrogen sulfide content |
≤ |
20 |
mg/Nm³ |
|
|||||
|
Content of mechanical impurities |
≤ |
30 |
mg/Nm³ |
|
|||||
|
Content of ammonia |
≤ |
20 |
mg/Nm³ |
|
|||||
|
Resin content |
≤ |
50 |
mg/m³ |
|
|||||
|
Water vapor concentration |
≤ |
20 |
mg/Nm³ |
|
|||||
|
Methane number |
> |
80 |
|
|
|||||