Series 16M33

Diesel engine model |
Nominal speed, min-1 |
Engine power |
Generator power |
Boost type |
Control type |
||||
Prime power (PRP), kW |
Emergency power (ESP), kW |
Prime power (PRP) |
Emergency power (ESP) |
||||||
kW |
kVA |
kW |
kVA |
||||||
16M33G1700/5 |
1500 |
1390 |
1530 |
1300 |
1600 |
1320 |
1650 |
T/Water-V |
CR |
16M33G1900/5 |
1500 |
1530 |
1680 |
1400 |
1750 |
1450 |
1800 |
T/Water-V |
CR |
16M33G2000/5 |
1500 |
1600 |
1720 |
1500 |
1850 |
1600 |
2000 |
T/Water-V |
CR |
16M33G2250/5 |
1500 |
1718 |
1898 |
1600 |
2000 |
1700 |
2100 |
T/Water-V |
CR |
16M33G1400/6 |
1800 |
1440 |
1580 |
1300 |
1600 |
1500 |
1850 |
T/Water-V |
CR |
16M33G1500/6 |
1800 |
1530 |
1680 |
1400 |
1750 |
1600 |
2000 |
T/Water-V |
CR |
16M33G1650/6 |
1800 |
1625 |
1785 |
1500 |
1850 |
1700 |
2100 |
T/Water-V |
CR |
16M33G1750/6 |
1800 |
1750 |
1920 |
1600 |
2000 |
1800 |
2250 |
T/Water-V |
CR |
Designation: T/Water-Air = Turbocharger / Water-Air type CVD, El.TNVD – mechanical fuel injection pump with electronic regulator, CR – accumulator type fuel system.
Diesel engine model |
Nominal speed Min-1 |
«L»
«W» Width, mm |
"N" Height, mm |
"Dry" Weight, kg |
|
16M33G1700/5 |
1500 |
3970 |
2240 |
2490 |
6450 |
16M33G1900/5 |
1500 |
3970 |
2240 |
2490 |
6450 |
16M33G2000/5 |
1500 |
3970 |
2240 |
2490 |
6450 |
16M33G1400/6 |
1800 |
3970 |
2240 |
2490 |
6450 |
16M33G1500/6 |
1800 |
3970 |
2240 |
2490 |
6450 |
16M33G1650/6 |
1800 |
3970 |
2240 |
2490 |
6450 |
16M33G1700/5 |
1500 |
3970 |
2240 |
2490 |
6450 |
|
|
||||
Emergency Standby Power (ESP) |
Prime Power (PRP) |
||||
Emergency Standby Power is the maximum power available to the varying load during the entire period of the mains failure. The average load factor during 24 hours of operation shall not exceed 70% of the ESP motor rated power. Typical operating hours of the engine are 200 hours per year, with a maximum usage of 500 hours per year. This includes an annual maximum of 25 hours per year at rated ESP power. No overload is allowed. The engine must not be used for continuous parallel operation. |
Prime power is the maximum power of the generating set when operating on a variable load, without limitation of operating time during the year with breaks for maintenance. For continuous operation over 24 h, the average permissible power should not exceed 70% of the prime power (PRP). When determining the average actual power, variable power values that are less than 30% of the prime power are taken as 30%, and idle time is not taken into account.
|
||||
Maintenance Scheduled maintenance every 500 engine hours. Increased service interval based on oil analysis. Operating time before major repairs is at least 32,000 engine hours. Engine life, taking into account three major repairs, is at least 120,000 engine hours. |